Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Journal of Chinese Physician ; (12): 1841-1844, 2019.
Article in Chinese | WPRIM | ID: wpr-800570

ABSTRACT

Objective@#To study the effect of color Doppler ultrasound (CDUS) combined with serum glucoside antigen 125 (CA125) on the diagnostic efficacy of patients with ovarian cancer.@*Methods@#A total of 78 patients with ovarian tumors admitted to our hospital from February 2012 to June 2018 were enrolled. Among them, 38 patients with malignant tumors and 40 patients with benign tumors were tested for CDUS and serum CA125. The characteristics of CDUS images and serum CA125 levels in patients with malignant tumors were analyzed by pathological examination as the gold standard. The diagnostic efficacy of CDUS combined with serum CA125 level detection and separate examination was analyzed.@*Results@#⑴ Characteristics of CDUS images: the size, location, texture, blood flow signal, resistance index, ascites, peritoneal implant nodule or enlarged lymph node of patients with malignant tumors were significantly different from those of benign tumors (P<0.05). ⑵ Serum CA125 level: the serum CA125 level of patients with malignant tumors was higher than that of patients with benign tumors (P<0.05). ⑶ Diagnostic results: among 78 patients with ovarian tumors, 33 cases of malignant tumors were detected by serum CA125, 45 cases of benign tumors, of which 5 cases were misdiagnosed, and 10 cases were missed. For example, CDUS detected 35 malignant tumors and 43 benign tumors, of which 6 were misdiagnosed and 9 were missed. A total of 43 malignant tumors and 35 benign tumors were detected, of which 6 were misdiagnosed and 1 was missed. ⑷ Diagnostic efficacy: the accuracy of CDUS combined with serum CA125 level detection (91.03%) was higher than that of the two groups (80.77% and 80.77%), but the difference was not statistically significant (P>0.05); the sensitivity of CDUS combined with serum CA125 level detection was 97.37%. The two were independently examined by 76.32% and 73.68% (P<0.05). The specificity of CDUS combined with serum CA125 was 85.00%, with no significant difference between the two groups (80.05%, 87.50%) (P>0.05).@*Conclusions@#The serum CA125 level of patients with ovarian cancer is abnormally elevated. The characteristics of CDUS images are different from those of benign tumors, which can effectively identify benign and malignant tumors. CDUS combined with serum CA125 level detection can significantly improve the diagnostic efficacy, and they can be used to judge the disease and symptom , and provide guidance for treatment and prognosis assessment.

2.
Journal of Chinese Physician ; (12): 1841-1844, 2019.
Article in Chinese | WPRIM | ID: wpr-824314

ABSTRACT

Objective To study the effect of color Doppler ultrasound (CDUS) combined with serum glucoside antigen 125 (CA125) on the diagnostic efficacy of patients with ovarian cancer.Methods A total of 78 patients with ovarian tumors admitted to our hospital from February 2012 to June 2018 were enrolled.Among them,38 patients with malignant tumors and 40 patients with benign tumors were tested for CDUS and serum CA125.The characteristics of CDUS images and serum CA125 levels in patients with malignant tumors were analyzed by pathological examination as the gold standard.The diagnostic efficacy of CDUS combined with serum CA125 level detection and separate examination was analyzed.Results (1)Characteristics of CDUS images:the size,location,texture,blood flow signal,resistance index,ascites,peritoneal implant nodule or enlarged lymph node of patients with malignant tumors were significantly different from those of benign tumors (P < 0.05).(2) Serum CA125 level:the serum CA125 level of patients with malignant tumors was higher than that of patients with benign tumors (P < 0.05).(3) Diagnostic results:among 78 patients with ovarian tumors,33 cases of malignant tumors were detected by serum CA125,45 cases of benign tumors,of which 5 cases were misdiagnosed,and 10 cases were missed.For example,CDUS detected 35 malignant tumors and 43 benign tumors,of which 6 were misdiagnosed and 9 were missed.A total of 43 malignant tumors and 35 benign tumors were detected,of which 6 were misdiagnosed and 1 was missed.(4) Diagnostic efficacy:the accuracy of CDUS combined with serum CA125 level detection (91.03%) was higher than that of the two groups (80.77% and 80.77%),but the difference was not statistically significant (P > 0.05);the sensitivity of CDUS combined with serum CA125 level detection was 97.37%.The two were independently examined by 76.32% and 73.68% (P <0.05).The specificity of CDUS combined with serum CA125 was 85.00%,with no significant difference between the two groups (80.05%,87.50%) (P >0.05).Conclusions The serum CA125 level of patients with ovarian cancer is abnormally elevated.The characteristics of CDUS images are different from those of benign tumors,which can effectively identify benign and malignant tumors.CDUS combined with serum CA125 level detection can significantly improve the diagnostic efficacy,and they can be used to judge the disease and symptom,and provide guidance for treatment and prognosis assessment.

3.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 223-227, 2015.
Article in Chinese | WPRIM | ID: wpr-637099

ABSTRACT

Objective To analyze the Doppler indices of uterine artery at 11-16 weeks normal gestation. Methods Two hundred and ninty-seven normal pregnant women were consecutively recruited to take routine ultrasound examination at 11-16 weeks' gestation. According to gestational week, they were divided into 6 groups (11-11+6 weeks, 12-12+6 weeks, 13-13+6 weeks, 14-14+6 weeks, 15-15+6 weeks, 16-16+6 weeks). According to the location of placenta, they were divided into 3 groups (central placenta, right placenta, left placenta). Finally, the pregnant women were divided into 5 groups (RI<0.60 group, 0.60-0.69 group, 0.70-0.79 group, 0.80-0.85 group and ≥ 0.85 group) according to resistance index (RI). Doppler indices of uterine artery were measured in each case. Results (1) The PIm, RIm, S/Dm values (the mean PI, RI, S/D values of bilateral uterine artery) were decreased with the progress of pregnancy, but the difference of the RIm, S/Dm were not significant. Only the decrease of PIm after 15 weeks was significant (P<0.05). The mean PIm of each group was:11 weeks 1.96±0.39, 12 weeks 1.94±0.45, 13 weeks 1.79±0.43, 14 weeks 1.79±0.36, 15 weeks 1.51±0.43, 16 weeks 1.50±0.30. (2) The PI, RI, S/D values of uterine artery with placenta attached were lower than the other side. In the left placenta group, bilateral RI difference was-0.04 (t=-3.095, P=0.005), bilateral PI difference was -0.24 (t=-3.232, P=0.004), bilateral S/D difference was-1.00 (t=-2.965, P=0.007);in the right placenta group, bilateral RI difference was 0.04 (t=6.159, P=0.000), bilateral PI difference was 0.43 (t=6.614, P=0.000), bilateral S/D difference was 2.05 (t=6.378, P=0.000);in the middle placenta group, bilateral RI difference was 0.02 (t=4.150, P=0.000), bilateral PI difference was 0.14 (t=4.475, P=0.000), bilateral S/D differencewas 0.54 (t=4.376, P=0.000). (3) According to the RI, incidence rates ofα-notch detected:in<0.60 group both sides were 0;in 0.60-0.69 group, left uterine artery was 0.08, right uterine artery was 0.08;in 0.70-0.79 group, left uterine artery was 0.34, right uterine artery was 0.31;in 0.80-0.85 group, left uterine artery was 0.65, right uterine artery was 0.72;in≥0.85 group, left uterine artery was 0.81, right uterine artery was 0.87. Conclusion The uterine artery Doppler indices of 11-16 weeks maybe a reliable and non-invasive method for examining uteroplacental perfusion.

4.
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-517872

ABSTRACT

OBJECTIVE:To prepare the compound chlorhexidine acetate ear drops for treating anaerobic and aerobic infections of antrum auris METHODS:The compound chlorhexidine acetate ear drops was prepared with mixed solvent of glycerin,alcohol and distilled water The contents of two main ingredients were determined by dual-wavelength isobestic point spectrophotometry and the stability of preparation was examined RESULTS:The average recovery of metronidazole was 99 34%(RSD=0 57%,n=6) and that of chlorhexidine acetate was 101 17%(RSD=0 88%,n=6) CONCLUSION:The new preparation is rational in formula,simple in quality control and good in stability and has good prospects in development

SELECTION OF CITATIONS
SEARCH DETAIL